Connection Diagram With EVS XHub SDTI Hub
Example of XNet2 network with a SDTI hub:
5.6.3. Required Conditions to Set up and Run
XNet
1. All systems on the network shall belong to the XT3 or XS servers, XStoreSE, XHub3
devices.
2. The SDTI advanced option code (for network client, master, or server modes) shall be
validated in the options list.
3. They shall all be running compatible software versions. Otherwise, warning message
is displayed.
4. The EVS video servers shall operate the same multi-essence configuration.
5. The SDTI speed parameter shall have the same value on all EVS servers (Network
page, SDTI section). The SDTI speed 2970 Mbps is available with EVS servers
equipped with H3X boards.
HARDWARE TECHNICAL REFERENCE MANUAL XS Server 12.05
5. Hardware Installation and Cabling 63